Configure Date And Time For The Ip Trunk 3.01 (And Later) Node - Nortel 1000 Fundamentals

Ip trunk fundamentals
Table of Contents

Advertisement

5
6
7
8
9
10
Once the Card Properties and Dialing Plan have been successfully
transmitted, the new Card Properties and Dialing Plan are automatically
applied to each IP trunk card. The IP Trunk 3.01 (and later) node is now
ready to make test calls if IP Trunk 3.01 (and later) and the ESN data have
been configured on the system.
Configure date and time for the IP Trunk 3.01 (and later) node
Follow the steps in
Trunk 3.01 (and later) node" (page 269)
the IP Trunk 3.01 (and later) node in order to have correct time and date
stamps in Operational Measurement (OM) reports, RADIUS Call Accounting
reports, error messages and error and trace logs.
Procedure 32
Configure the date and time for the IP Trunk 3.01 (and later) node
Step
1
2
3
Copyright © 2007, Nortel Networks
.
Configure date and time for the IP Trunk 3.01 (and later) node 269
Click the Start transmit button.
Monitor progress in the Transmit Control window. Confirm that the
Card Properties and Dialing Plan are transmitted successfully to all
the IP trunk cards, which are identified by TNs.
When the transmission is complete, click the Close button.
Use the LD 32 ENLC command to enable the IP trunk cards in the
IP Trunk 3.01 (and later) node.
In the IP Telephony Gateway - ISDN IP Trunk window, select View
> Refresh. The card status should now show "Enabled."
Verify the TN, ELAN network interface MAC address, IP addresses,
and D-Channel for each Media Card 32-port and ITG-Pentium
24-port trunk card. Compare the configuration data with the data on
the IP Trunk 3.01 (and later) Installation Summary Sheet.
Procedure 32 "Configure the date and time for the IP
Action
Select the IP Trunk 3.01 (and later) node for which the date and time
is to be configured from the list in the upper part of the IP Telephony
Gateway - ISDN IP Trunk window.
Double-click Leader 0 from the list in the lower part of the window.
The ITG Card Properties window – Maintenance tab opens.
Click the Set Node Time... button.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
—End—
to configure the date and time on

Advertisement

Table of Contents
loading

Table of Contents