Remove Existing I/O Panel Filter Adapter - Nortel 1000 Fundamentals

Ip trunk fundamentals
Table of Contents

Advertisement

194 Install and configure IP Trunk 3.01 (and later) node
Remove existing I/O panel filter adapter
The standard I/O filter adapter is shielded metal with a black plastic insert
connector. The NTCW84JA adapter uses yellow warning labels to indicate
EMC filtering modifications and which MDF connection points can support
100BaseT connection.
Follow the steps in
adapter" (page 194)
Procedure 8
Removing the existing I/O panel filter adapter
Step
1
2
3
4
5
6
Copyright © 2007, Nortel Networks
.
Procedure 8 "Removing the existing I/O panel filter
to remove the existing I/O panel filter adapter.
Action
Remove the ITG pack, or any other IPE pack, from the IPE shelf
card slot corresponding to the I/O Panel connector to be removed.
Make sure to use the I/O panel connector which corresponds to the
left slot number of the DCHIP card.
Remove the NT8D81AA Backplane to I/O Panel ribbon cable
assembly which is connected to the backplane side of the existing
block by releasing the latching pins on the filter block and pulling the
NT8D81AA cable away.
Unscrew the existing filter adapter from the I/O panel. There is one
screw on the lower front of the adapter and one screw on the upper
back of the adapter. Remove the adapter.
Re-position the new NTCW84JA filter adapter in the now vacant I/O
panel opening. (See
Connector Block" (page
Attach the new NTCW84JA to the I/O panel by securely fastening
the top back screw and the bottom front screw.
Reconnect the NT8D81AA cable and secure it in place by snapping
shut the locking latches provided on the NTCW84JA connector.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Figure 35 "NTCW84JA 50 pin I/O Panel Filter
195).)
—End—