(7) Defective Image of Regular Interval (See Figure 6-2 E)
Interval
Problem
3.709 inches
Image Drum
2.504 inches
Developing Roller
2.276 inches
Toner Supply Roller
1.732 inches
Charging Roller
4.453 inches
Fuser Upper Roller
4.453 inches
Fuser Lower Roller
2.276 inches
Transfer Roller
Note! The life counters of the I/D units, fuser unit and belt cassette unit are automatically reset upon replacement of the units, respectively.
Service Guide - C7000 Series
Chapter 6 Troubleshooting Procedures
Copyright 1999, Okidata, Division of OKI America, Inc. All rights reserved.
Troubleshooting
Replace the image drum unit.
Replace the image drum unit.
Replace the image drum unit.
Replace the image drum unit.
Replace the fuser unit.
Replace the fuser unit.
Replace the belt Assy
Page: 149