Brocade Communications Systems StoreFabric SN6500B Administrator's Manual page 285

Brocade fabric os encryption administrator's guide v7.1.0 (53-1002721-01, march 2013)
Hide thumbs Also See for StoreFabric SN6500B:
Table of Contents

Advertisement

3. If the replaced FS8-18 blade is in member node, invoke the following command to reclaim the
4. Issue commit.
5. Replace the old FS8-18 blade with the new FS8-18 blade and reconnect the FC cables and I/O
6. Insert the new FS8-18 blade in the same slot of the chassis that was used by the old FS8-18
7.
8. Invoke slotpoweroff and slotpoweron commands.
9. If the encryption group (EG) has a system card authentication enabled, you need to reregister
10. Initialize the new EE using the following command:
11. Register the new EE using the following command:
12. Enable the new EE using the following command:
13. Verify the new FS8-18 blade EE has the same master key as the other EEs in the EG using the
14. If a master key is not present, restore the master key from a backed up copy. Procedures will
15. Check the EE state using the following command to ensure that the EE is online.
Fabric OS Encryption Administrator's Guide (SKM/ESKM)
53-1002721-01
base WWN.
FabricAdmin:switch> cryptocfg --reclaimWWN –EE <failed EE WWN> <slot number>
FabricAdmin:switch> cryptocfg --commit
Link cables.
blade. Reconnect the I/O sync ports to the same private LAN as the I/O sync ports of the old
blade, and confirm that the IP address of the I/O sync ports (Ge0 and Ge1) is same as the
previous IP address.
Zeroize the new encryption engine (EE) using the following command:
FabricAdmin:switch> cryptocfg –-zeroizeEE [slotnumber]
FabricAdmin:switch> slotpoweroff [slotnumber]
FabricAdmin:switch> slotpoweron [slotnumber]
the system card through the BNA client for the new EE. Refer to Chapter 2, Configuring
Encryption Using the Management Application."
FabricAdmin:switch> cryptocfg –-initEE [slotnumber]
FabricAdmin:switch> cryptocfg -–regEE [slotnumber]
FabricAdmin:switch> cryptocfg –-enableEE [slotnumber]
following command:
FabricAdmin:switch> cryptocfg --show –groupmember –all
differ depending on the backup media used (for example, recovery smart cards, from the key
vault, from a file on the network, or a file on a USB-attached device). Refer to Chapter 2,
Configuring Encryption Using the Management Application."
FabricAdmin:switch> cryptocfg –show –localEE
FS8-18 blade removal and replacement