Using Colorport For Color Calibration - Xerox 490 Color Management Manual

Color continuous feed printing system
Hide thumbs Also See for 490:
Table of Contents

Advertisement

Xerox 490/980 CCF Printing System

Using ColorPort for Color Calibration

Open the Colorport software. Select [Start: Programs: Colorport] on your PC or select
[Colorport.exe] on the desktop.
1. Select the [Measure Target] tab.
2. Select the Target pull down menu. Select the name of the first test pattern, (ex:
EyeOneiSis_up_Calib.rnd_1). The "EyeOneiSis" refers to the measuring device.
3. Select the measuring device [X-Rite Eye-One iSis].
4. Select [Connect].
5. After the pop-up window appears, place the test pattern into the reader, image facing up.
You may need to hold the test pattern as the reader begins.
6. When the EyeOneiSis has completed the reading of the printed pattern, select [Save Data].
7. Select the Format pull down menu and select [CGATS]. Spectral Range is 400nm - 700nm
and Value Scale is 0-100.
8. Select [Save].
9. A save screen will open. Select the name that matches the name of the test pattern
(upstream, downstream, error diffusion, halftone dot). Older files can be used as naming
templates to create a name. An example of how a file should be named is:
Date_Printer_Filetype_Scan #.txt.
10. Select [Save]. A pop-up window will appear asking if you wish to replace it, select [Yes].
11. Repeat the above steps (except steps 2 and 3) for each test pattern. When completed, close
Colorport.exe.
12. On the CMS Option tool, select the [Create Calibration Data] tab.
13. Select paper name.
14. Specify a measured data file for Upstream (Printer1):
a.
Halftone Dot: select [Browse] and select file [EyeOneiSis_Cal_299_up_(HD)] with
today's date.
b.
Error Diffusion: select [Browse] and select file [EyeOneiSis_Cal_299_up_(ERRD)] with
today's date.
15. Specify a measured data file for Downstream (Printer2):
a.
Halftone Dot: select [Browse] and select file [EyeOneiSis_Cal_299_dn_(HD)] with
today's date.
b.
Error Diffusion: select [Browse] and select file [EyeOneiSis_Cal_299_dn_(ERRD)] with
today's date.
16. Select [Execute] and then [Yes]. When completed, select [OK] and close the previous
window.
Color Management Guide
Color Calibration Using ColorPort Utility Software
6-3