System BIOS
Setup Item
Clear System Event
Log
FRB-2 Enable
O/S Boot Watchdog
Timer
O/S Boot Watchdog
Timer Policy
O/S Boot Watchdog
Timer Timeout
Console Redirection
System Information
4.3.2.4.1
Console Redirection Screen
The Console Redirection screen provides a way to enable or disable console redirection and to
configure the connection options for this feature.
To access this screen from the Main screen, select Server Management. Select the Console
Redirection option from the Server Management screen.
Revision 1.8
Options
Enabled
Clears the System Event Log. All current entries will
be lost.
Disabled
Note: This option will be reset to [Disabled] after a
reboot.
Fault Resilient Boot (FRB).
Enabled
BIOS programs the BMC watchdog timer for
Disabled
approximately 6 minutes. If BIOS does not complete
POST before the timer expires, the BMC will reset the
system.
Enabled
BIOS programs the watchdog timer with the timeout
value selected. If the OS does not complete booting
Disabled
before the timer expires, the BMC will reset the
system and an error will be logged.
Requires OS support or Intel Management Software.
If the OS watchdog timer is enabled, this is the system
Power Off
action taken if the watchdog timer expires.
Reset
[Reset] - System performs a reset.
[Power Off] - System powers off.
5 minutes
If the OS watchdog timer is enabled, this is the
timeout value BIOS will use to configure the watchdog
10 minutes
timer.
15 minutes
20 minutes
View/Configure console redirection information and
settings.
View system information
Intel Order Number: E14960-009
Intel® Server Boards S3200SH/S3210SH TPS
Help Text