Intel DBS1200KP Product Manual
Intel DBS1200KP Product Manual

Intel DBS1200KP Product Manual

Product guide
Table of Contents

Advertisement

®
Intel
Server Board S1200KP
Product Guide
Order Number: G39481-003

Advertisement

Table of Contents
loading

Summary of Contents for Intel DBS1200KP

  • Page 1 ® Intel Server Board S1200KP Product Guide Order Number: G39481-003...
  • Page 2 ® Copies of documents which have an ordering number and are referenced in this document, or other Intel literature, may be obtained from Intel Corporation by going to the World Wide Web site at: http://www.intel.com/...
  • Page 3: Preface

    Preface Preface This Product Guide gives information about board layout, component installation, BIOS update, ® and regulatory requirements for Intel Server Board S1200KP. Intended Audience The Product Guide is intended for technically qualified personnel. It is not intended for general audiences.
  • Page 4 Preface Term Description Megabyte (1,048,576 bytes) Megabit (1,048,576 bits) Megahertz (one million hertz) ® Intel Server Board S1200KP Product Guide...
  • Page 5: Table Of Contents

    Terminology ......................iii Server Board Features ......................1 Supported Operating Systems ....................3 Server Board Components ....................4 Processor ..........................6 ® Intel C206 Express Chipset ....................7 Main Memory ........................7 Graphics Subsystem ......................8 Integrated Graphics ...................... 8 ®...
  • Page 6 Setting the BIOS Configuration Jumper ................39 Clearing Passwords ......................40 Replacing the Battery ......................41 Updating the BIOS......................43 ® Updating the BIOS with the Intel Flash Memory Update Utility ........... 43 Obtaining the BIOS Update File.................. 43 ® Updating the BIOS with the Intel Flash Memory Update Utility ........
  • Page 7 Figures Figures ® Figure 1. Intel Server Board S1200KP Components ............4 Figure 2. LAN Connector LEDs ................... 10 Figure 3. Location of the Standby Power Indicator .............. 16 Figure 4. Installing the I/O Shield..................20 ® Figure 5. Intel Server Board S1200KP Mounting Screw Hole Locations ......
  • Page 8 Tables Tables Table 1. Feature Summary ....................1 ® Table 2. Intel Server Board S1200KP Components ............. 5 Table 3. LAN Connector LEDs .................... 10 Table 4. Chassis Intrusion Header Signal Names ............... 34 Table 5. USB 2.0 Header Signal Names ................35 Table 6.
  • Page 9 Tables <This page is intentionally left blank.> ® Intel Server Board S1200KP Product Guide...
  • Page 10: Server Board Features

    C206 Platform Controller Hub (PCH) Chipset Chipset  Integrated graphics support for processors with Intel ® Graphics Graphics Technology: ― DVI-I  Discrete graphics support for PCI Express* 2.0 x16 (with Intel ® ® Xeon E3-1200 ® Core™ i3 Processors) or PCI Express*...
  • Page 11  Two fan sense inputs used to monitor fan activity  Fan speed control Notes: ® Pairing a mini-ITX chassis and more than 65W TDP processor with the supplied standard Intel thermal ® solution may not meet Intel ’s thermal requirement standard. Please verify that your thermal solution and chassis will meet the necessary thermal requirements.
  • Page 12: Supported Operating Systems

    Microsoft Windows 7* Home Basic 32-bit edition  Microsoft Windows Server 2008 R2 SP1* with Hyper-v  Microsoft Windows Small Business Server 2011 Essentials*  Redhat* Enterprise Linux 6.0  SUSE* Linux Enterprise Server 11 ® Intel Server Board S1200KP Product Guide...
  • Page 13: Server Board Components

    Server Board Features Server Board Components ® Figure 1 shows the approximate location of the major components on Intel Server Board S1200KP. ® Figure 1. Intel Server Board S1200KP Components ® Intel Server Board S1200KP Product Guide...
  • Page 14: Table 2. Intel Server Board S1200Kp Components

    Server Board Features ® Table 2. Intel Server Board S1200KP Components Item/callout Description Back panel connectors Processor core power connector (2 x 2) Front panel USB 2.0 header BIOS Setup configuration jumper block SATA connectors ® Intel C206 Chipset Front panel USB 2.0 header...
  • Page 15: Processor

    Server Board and must be purchased separately. The processor connects to the Server Board through the LGA1155 socket. NOTE ® The product codes of DBS1200KP and BBS1200KP can only support Intel ® ® Xeon E3-1200 Processors or the 2 Generation Intel Core™...
  • Page 16: Intel C206 Express Chipset

    Intel C206 Chipset with Direct Media Interface (DMI) interconnect provides interfaces to the ® processor and the USB, SATA, LPC, LAN and PCI Express* interfaces. The Intel C206 Chipset is a centralized controller for the board’s I/O paths. Main Memory NOTE ®...
  • Page 17: Graphics Subsystem

    Server Board Features Graphics Subsystem ® The board supports system graphics through either Intel HD Graphics or a PCI Express* 2.0 x16 ® ® ® (with Intel Xeon E3-1200 Processors or the 2 Generation Intel Core™ i3 Processors) or PCI ®...
  • Page 18 Supports PCI Express* GEN1 frequency of 2.5 GHz resulting in 2.5 Gb/s each direction (250 MB/s) per lane. The maximum theoretical bandwidth on the interface is 4 GB/s in each direction, simultaneously, for an aggregate of 8 GB/s when operating in x16 GEN1 mode. ® Intel Server Board S1200KP Product Guide...
  • Page 19: Lan Subsystem

     RJ-45 LAN connector with integrated status LEDs LAN software and drivers are available at http://downloadcenter.intel.com/. Two LEDs are built into the RJ-45 LAN connector located on the back panel (see Figure 2). These LEDs indicate the status of the LAN as shown in Table 3.
  • Page 20: Expandability

    Server Board Features Expandability ® ® ® Intel Server Board S1200KP provides one PCI Express* 2.0 x16 (with Intel Xeon E3-1200 ® ® Processors or the 2 Generation Intel Core™ i3 Processors) or PCI Express* 3.0 x 16 (with Intel ®...
  • Page 21: Hardware Management

    For instructions on resetting the password, go to Clearing Passwords on page 40. Hardware Management ® The hardware management features of Intel Server Board S1200KP enable the board to be compatible with the Wired for Management (WfM) specification. The board has several hardware management features including the following: ...
  • Page 22: Hardware Monitoring And Fan Speed Control

    Fan speed controllers and sensors are integrated into the legacy I/O controller.  ® Thermal sensors in the processor and Intel C206 PCH, as well as near the processor voltage regulators and system memory.  Monitoring of system voltages to detect levels above or below acceptable values ...
  • Page 23: Hardware Support

    LAN wakeup capabilities enable remote wake-up of the computer through a network. The LAN subsystem monitors network traffic and upon detecting a Magic Packet* frame, it asserts a wake-up signal that powers up the computer. ® Intel Server Board S1200KP Product Guide...
  • Page 24: Instantly Available Pc Technology

    For example, when this green LED is lit, standby power is still present at the memory module sockets and the PCI Express* connector. ® Intel Server Board S1200KP Product Guide...
  • Page 25: Figure 3. Location Of The Standby Power Indicator

    Server Board Features Figure 3. Location of the Standby Power Indicator For more information on standby current requirements for the Server Board, refer to the Technical Product Specification at http://www.intel.com/products/server. ® Intel Server Board S1200KP Product Guide...
  • Page 26: Wake From Usb

    When the battery voltage drops below a certain level, the BIOS Setup program settings stored in CMOS RAM (for example, the date and time) might not be accurate. Replace the battery with an equivalent one. Go to page 41 for instructions on how to replace the battery. ® Intel Server Board S1200KP Product Guide...
  • Page 27: Installing And Replacing Server Board Components

    ESD workstation using an antistatic wrist strap and a conductive foam pad. If such a station is not available, you can provide some ESD protection by wearing an antistatic wrist strap and attaching it to a metal part of the computer chassis. ® Intel Server Board S1200KP Product Guide...
  • Page 28: Installation Precautions

    Installing and Replacing Server Board Components Installation Precautions ® When you install and test the Intel Server Board, observe all warnings and cautions in the installation instructions. To avoid injury, be careful of:  Sharp pins on connectors  Sharp pins on printed circuit assemblies ...
  • Page 29: Installing The I/O Shield

    Figure 4. Press the shield into place so that it fits tightly and securely. If the shield does not fit, obtain a properly sized shield from the chassis supplier. Figure 4. Installing the I/O Shield ® Intel Server Board S1200KP Product Guide...
  • Page 30: Installing And Removing The Server Board

    Refer to your Chassis Manual for instructions on installing and removing the Server Board. ® Figure 5 shows the location of the mounting screw holes for Intel Server Board S1200KP. ®...
  • Page 31: Installing And Removing A Processor

    1. Observe the precautions in "Before You Begin" in page 18. 2. Unlatch the processor socket lever by pushing it down and away from the socket (Figure 6, A, B). Figure 6. Unlatch the Socket Lever ® Intel Server Board S1200KP Product Guide...
  • Page 32: Figure 7. Lift The Load Plate

    3. Rotate the socket lever to lift the load plate away from the socket (Figure 7, A). Make sure that the load plate is in the fully open position (Figure 7, B) while being careful not to damage adjacent components. Do not touch the socket contacts. Figure 7. Lift the Load Plate ® Intel Server Board S1200KP Product Guide...
  • Page 33: Figure 8. Remove The Processor From The Protective Cover

    6. Carefully lower the socket lever (Figure 10, A) while making sure that the front edge of the load plate slides under the shoulder screw cap as the lever is lowered. Latch the socket lever ® Intel Server Board S1200KP Product Guide...
  • Page 34: Figure 10. Secure The Load Plate In Place

    7. Pick up the socket cover and remove it from the server board. NOTE Do not discard the socket cover; save it for possible future use. Always replace the socket cover if you remove the processor from the socket. ® Intel Server Board S1200KP Product Guide...
  • Page 35: Installing A Processor Fan Heat Sink

    Installing a Processor Fan Heat Sink ® Intel Server Board S1200KP has mounting holes for a processor fan heat sink. For instructions on how to attach the processor fan heat sink to the Server Board, refer to the boxed processor manual or boxed thermal solution manual.
  • Page 36: Installing And Removing System Memory

    Installing and Replacing Server Board Components Installing and Removing System Memory NOTE ® To be fully compliant with all applicable Intel DRAM memory specifications, the board requires DIMMs that support the Serial Presence Detect (SPD) data structure. The server board has two 240-pin DDR3 DIMM sockets providing Channel A and Channel B. For dual-channel performance, install a matched pair of DIMMs equal in speed and size (see Figure 12).
  • Page 37: Installing Dimms

    To make sure you have the correct DIMM, place it on the illustration of the DDR3 DIMM in Figure 13. All the notches should match with the DDR3 DIMM. Figure 13. Use DDR3 DIMMs ® Intel Server Board S1200KP Product Guide...
  • Page 38: Figure 14. Installing A Dimm

    7. Position the DIMM above the socket. Align the small notch at the bottom edge of the DIMM with the keys in the socket (see inset in Figure 14). 8. Insert the bottom edge of the DIMM into the socket. ® Intel Server Board S1200KP Product Guide...
  • Page 39: Removing Dimms

    Depending on the over-current protection of the power supply, certain Server Board components and/or traces may be damaged. ® Intel Server Board S1200KP Product Guide...
  • Page 40: Figure 15. Installing A Pci Express* X16 Graphics Card

    3. Secure the card’s metal bracket to the chassis back panel with a screw (Figure 15, B). 4. Connect a monitor to the graphics card according to the manufacturer’s instructions. Figure 15. Installing a PCI Express* x16 Graphics Card ® Intel Server Board S1200KP Product Guide...
  • Page 41: Removing A Pci Express* X16 Graphics Card

    4. Push the card ejector lever down using the tip of a pencil or similar tool (Figure 16, B) in the notch. This will release the card from the connector (C). 5. Pull the card straight up to remove it. Figure 16. Removing a PCI Express* x16 Graphics Card ® Intel Server Board S1200KP Product Guide...
  • Page 42: Connecting Sata Drives

    2. Attach one end of the SATA cable to one of the SATA connectors on the board (Figure 17, A) and attach the other end of the cable to the SATA drive data connector (Figure 17, B). Figure 17. Connecting a SATA Drive ® Intel Server Board S1200KP Product Guide...
  • Page 43: Connecting To The Internal Headers

    Before connecting cables to any of the internal headers, observe the precautions in “Before You ® Begin” on page 18. Figure 18 shows the location of the internal headers and connectors on Intel Server Board S1200KP. Figure 18. Internal Headers Chassis Intrusion Header Figure 18, A shows the location of the chassis intrusion header.
  • Page 44: Front Panel Usb 2.0 Headers

    LED cable, connect it to this header. Table 7 shows the pin assignments for the alternate front panel header. Table 7. Alternate Front Panel Power LED Header Signal Names Signal Name In/Out Front panel LED+ No pin Front panel LED- ® Intel Server Board S1200KP Product Guide...
  • Page 45: Low Pin Count (Lpc) Debug Header

    Table 8. LPC Debug Header Signal Name Signal Name CK_33M_DEBUG PLTRST# LFRAME# LAD0 LAD1 LAD2 LAD3 +3.3 V +3.3 V Not Connected +3.3 V ® Intel Server Board S1200KP Product Guide...
  • Page 46: Connecting Chassis Fan And Power Supply Cables

    Connecting a Chassis Fan Connect the chassis fan cable to the chassis fan header on the Server Board. Figure 19 shows the location of the chassis fan header. Figure 19. Location of the Chassis Fan Header ® Intel Server Board S1200KP Product Guide...
  • Page 47: Connecting Power Supply Cables

    2. Connect the 12 V processor core voltage power supply cable to the 2 x 2 pin connector (Figure 20, A). 3. Connect the main power supply cable to the 2 x 12 pin connector (Figure 20, B). ® Intel Server Board S1200KP Product Guide...
  • Page 48: Setting The Bios Configuration Jumper

    Moving the jumper with the power on may result in unreliable computer operation. Figure 21 shows the location of the Server Board’s BIOS configuration jumper block. Figure 21. Location of the BIOS Configuration Jumper Block ® Intel Server Board S1200KP Product Guide...
  • Page 49: Clearing Passwords

    10. Turn off the computer. Disconnect the computer’s power cord from the AC power source. 11. Remove the computer cover. 12. To restore normal operation, place the jumper on pins 1-2 as shown below. ® Intel Server Board S1200KP Product Guide...
  • Page 50: Replacing The Battery

    6. To install the new battery, remove the paper backing (Figure 22, C) from the battery adhesive pad, attach the battery to the I/O stack, and connect the wires (Figure 22, E) to the server board. 7. Replace the computer cover. ® Intel Server Board S1200KP Product Guide...
  • Page 51: Figure 22. Removing The Battery

    Installing and Replacing Server Board Components Figure 22. Removing the Battery ® Intel Server Board S1200KP Product Guide...
  • Page 52: Updating The Bios

    ® Intel Flash Memory Update Utility ® You can obtain either of these files through your computer supplier or by navigating to the Intel ® Server Board S1200KP page on the Intel World Wide Web site Download Center at http://downloadcenter.intel.com.
  • Page 53 (optional) to a bootable USB flash drive or other bootable USB media. 2. Configure the BIOS or use the F10 option during POST to boot to the USB device. 3. Manually run the IFLASH.EXE file from the USB device and manually update the BIOS. ® Intel Server Board S1200KP Product Guide...
  • Page 54: Updating The Bios Using The F7 Function Key

    You can obtain the Recovery BIOS Update file through your computer supplier or by navigating to ® ® the Intel Server Board S1200KP page on the Intel World Wide Web site Download Center at http://downloadcenter.intel.com. On the S1200KP page, click on the “BIOS Update” link and then select the Recovery BIOS Update file.
  • Page 55: Appendix A: Error Messages And Indicators

    Appendix A: Error Messages and Indicators Appendix A: Error Messages and Indicators ® Intel Server Board S1200KP reports POST errors in two ways:  By sounding a beep code and blinking the front panel power LED  By displaying an error message on the monitor BIOS Error Codes Whenever a recoverable error occurs during POST, the BIOS causes the board’s speaker to beep...
  • Page 56: Bios Error Messages

    Memory Size Decreased Memory size has decreased since the last boot. If no memory was removed, then memory may be bad. No Boot Device Available System did not find a device to boot. ® Intel Server Board S1200KP Product Guide...

This manual is also suitable for:

S1200kp