CR Motor Removal

3.2.5.5
1. Remove the printer mechanism. (See section 3.2.4.)
2. Release the timing belt. (See section 3.2.5.2.)
3. Remove the 3 screws securing the CR motor to the upper frame, and then remove the CR
motor.

PF Motor Removal

3.2.5.6
1. Remove the printer mechanism. (See section 3.2.4.) ~
2. Remove the 2 CBN (M3x6) screws and then remove the PFmotor.
Rev. A
Figure 3-14. CR Motor Removal
Figure 3-15. PF Motor Removal
3-13