4.2.7.1 CR Motor Assembly Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Remove the tension spring, 8.10 and motor bracket and release the tension of the
timing belt.
3.
Remove the timing belt from the pulley of the CR motor assembly.
4.
Rotate the CR motor assembly with the motor bracket clockwise to remove it.
Timing Belt
Figure4-11. CR Motor Assembly Removal
A D J U S T M E N T
When the CR motor assembly is replaced, perform Bi-D adjustment.
R E Q U I R E D
Disassembly and Assembly
Tension Spring, 8.10
CR Motor Assembly
Base Frame

4.2.7.2 Platen Removal

1.
Remove the printer mechanism. (See 4.2.3 "Printer Mechanism Removal".)
2.
Remove the platen grounding wire from the platen.
3.
Release 1 hook at the rotating hole of the combination gear 17.5, 27 and remove the
gear from the right frame.
Figure4-12. Hook at the Combination Gear 17.5, 27
4.
Rotate right and left bushing, 11 and remove them off from the right / left frame.
5.
Remove the platen.
Disassembly and Assembly
To unhook the combination gear 17.5, 27, hold
it and pull it to the arrow direction.
Revision C
Combination gear, 17.5, 27
Gear, 34
81