1.3 INTERFACE SPECIFICATIONS

The Stylus Color is standard-equipped with an 8-bit parallel and serial interface.

1.3.1 Serial interface Specifications

Data format:
Synchronization:
Handshaking:
Signal level:
Adaptable connector:
Data transmission timing:
BUSY
DATA
STROBE
Note:
Transition time (rise time and fall time) of every input signal must be less than 0.2 ps.
The Busy signal is active (HIGH) under the following conditions:
- During data reception (See Figure 1-7.)
- When the input buffer is full
- When the INIT input signal is active
- During initialization
- When the ERROR or PE signal is active
- During the self-test mode
- During the demonstration mode
- During the default setting mode
- When a fatal error occurs
The ERROR signal is active (LOW) under the following conditions:
- When a paper-out error occurs
- When a no ink cartridge error occurs
- When a fatal error occurs
The PE signal is active (HIGH) under the following conditions:
- When a paper-out error occurs
- When a fatal error occurs
Rev. A
8-bit parallel
By STROBE pulse synchronization
By BUSY and ACKNLG signals
TTL compatible level
36 pin 57-30360 (Amphenol) or equivalent
See Figure 1-7.
L_-

Figure 1-7. Data Transmission Timing

0.5 ps (minimum)
0.5 IJS (minimum)
0.5 ps (minimum)