Epson S1C88650 Technical Manual page 85

Hewlett-packard cmos 8-bit single chip microcomputer technical manual
Table of Contents

Advertisement

SCS0, SCS1: 00FF48H•D3, D4
Select the clock source according to Table 5.8.9.3.
Table 5.8.9.3 Clock source selection
SCS1
SCS0
1
1
1
0
0
1
0
0
SCS0 and SCS1 can also be read out.
In the clock synchronous slave mode, setting of this
register is invalid.
At initial reset, this register is set to "0" (f
SDP: 00FF4BH•D0
Selects the serial data input/output permutation.
When "1" is written: MSB first
When "0" is written: LSB first
Reading:
Select whether the data input/output permutation
will be MSB first or LSB first.
At initial reset, SDP is set to "0" (LSB first).
STPB: 00FF4BH•D1
Selects the stop bit length for asynchronous data
transfer.
When "1" is written: 2 bits
When "0" is written: 1 bit
Reading:
STPB is the stop bit select register that is effective in
asynchronous mode. When "1" is written to STPB,
the stop bit length is set to 2 bits, and when "0" is
written, it is set to 1 bit.
In clock synchronous mode, no start/stop bits can
be added to transfer data. Therefore, setting STPB
becomes invalid.
At initial reset, STPB is set to "0" (1 bit).
EPR: 00FF48H•D6
Selects the parity function.
When "1" is written: With parity
When "0" is written: Non parity
Reading:
Selects whether or not to check parity of the
received data and to add a parity bit to the trans-
mitting data. When "1" is written to EPR, the most
significant bit of the received data is considered to
be the parity bit and a parity check is executed. A
parity bit is added to the transmitting data. When
"0" is written, neither checking is done nor is a
parity bit added.
Parity is valid only in asynchronous mode and the
EPR setting becomes invalid in the clock synchro-
nous mode.
At initial reset, EPR is set to "0" (non parity).
S1C88650 TECHNICAL MANUAL
5 PERIPHERAL CIRCUITS AND THEIR OPERATION (Serial Interface)
Clock source
Programmable timer
f
/ 4
OSC3
f
/ 8
OSC3
f
/ 16
OSC3
/16).
OSC3
Valid
Valid
Valid
PMD: 00FF48H•D5
Selects odd parity/even parity.
When "1" is written: Odd parity
When "0" is written: Even parity
Reading:
When "1" is written to PMD, odd parity is selected
and even parity is selected when "0" is written. The
parity check and addition of a parity bit is only
valid when "1" has been written to EPR. When "0"
has been written to EPR, the parity setting by PMD
becomes invalid.
At initial reset, PMD is set to "0" (even parity).
TXEN: 00FF49H•D0
Sets the serial interface to the transmitting enable
status.
When "1" is written: Transmitting enable
When "0" is written: Transmitting disable
Reading:
When "1" is written to TXEN, the serial interface
shifts to the transmitting enable status and shifts to
the transmitting disable status when "0" is written.
Set TXEN to "0" when making the initial settings of
the serial interface and similar operations.
At initial reset, TXEN is set to "0" (transmitting
disable).
TXTRG: 00FF49H•D1
Functions as the transmitting start trigger and the
operation status indicator (transmitting/stop
status).
When "1" is read:
When "0" is read:
When "1" is written: Transmitting start
When "0" is written: Invalid
Starts the transmitting when "1" is written to
TXTRG after writing the transmitting data.
TXTRG can be read as the status. When set to "1", it
indicates transmitting operation, and "0" indicates
transmitting stop.
At initial reset, TXTRG is set to "0" (during stop).
RXEN: 00FF49H•D2
Sets the serial interface to the receiving enable status.
When "1" is written: Receiving enable
When "0" is written: Receiving disable
Reading:
When "1" is written to RXEN, the serial interface
shifts to the receiving enable status and shifts to the
receiving disable status when "0" is written.
Set RXEN to "0" when making the initial settings of
the serial interface and similar operations.
At initial reset, RXEN is set to "0" (receiving disable).
EPSON
Valid
Valid
During transmitting
During stop
Valid
77