Distribution Cabinet; Module Mounting - Emerson SAG581126000 System Application Manual

Table of Contents

Advertisement

SAG581126000
Issue AD, November 23, 2009
List
Part Number
No.
62
58112600062
71
58112600071
72
58112600072
73
58112600073
74
58112600074
75
58112600075
76
58112600076
77
58112600077
78
58112600078
92
58112600092
93
58112600093
Notes:
1) This power system must consist of a minimum configuration of...
(1) List 1
(1) List 10, 11, 12, or 13
(1) List 21, 22, 23, or 24
(1) List 30 equipped w/ List 50's
A maximum of one supplemental bay (List 2 or 5) may be added to the system.
2) Separately order one relay rack for each bay (List 1, 2, and 5). See
DESCRIPTIONS section for available relay racks. Distribution Panels, Rectifier Modules (PCUs),
Converters, and Module Mounting Assembly list options must be specified when ordering. Module
Mounting Assembly must be ordered separately.
Note: System components may be ordered without a relay rack. When ordered without a relay rack, the
system is mounted on shipping brackets bolted to a shipping skid. The shipping brackets can
mount a system up to 20U high.
3) Includes Module Mounting Assembly to Distribution Cabinet interconnect components only. Module
Mounting Assembly is not included in List 30. Order Module Mounting Assembly separately per
PD588705101, PD588705102, PD588705103, PD588705104.
4) Use alarm cable P/N 514327 (15' 0" cable) when List 71 is not ordered (List 1 provides this cable). For a
longer cable, P/N 514380 (60') is available.
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
Description
Optional Model C24/48-1500 DC-DC Converter Module
(for use in List 30 and 31).
Audible Alarm and Alarm Termination Card.
MCA Interface Modem Option.
MCA Interface WinLink Software.
MCA Interface Combination Modem/RS-232 Option.
MCA Interface Ethernet Option
(WinLink Compatible, Web Interface).
MCA Interface Ethernet Option
(WinLink Compatible, Web Interface, SNMP).
MCA Interface Ethernet Option
(WinLink Compatible, Web Interface, Battery Monitoring).
MCA Interface Ethernet Option
(WinLink Compatible, Web Interface, SNMP, Battery
Monitoring).
Battery Stand System
Battery Tray, Pre-Cabled.
Page 10 of 123
System Application Guide
Spec. No. 581126000 (Model 700
Mounting
Positions
(1U = 1-3/4")
--
--
--
--
--
--
--
--
--
--
As requested
Table 1
in the ACCESSORY
)
NVBA
Home
Notes
--
4
--
--
--
--
--
--
--
--
--