List Options (Letters) (Distribution Bus Arrangements)

If Low Voltage Disconnect (LVD) is required, each distribution row that is to operate from an LVD
must have an LVD provided in the specific panel ordered for that row.
Rows are numbered one through four (A through D) from bottom to top.
List
Part Number
No.
AA
581126000AA
AB
581126000AB
AC
581126000AC
AD
581126000AD
AE
581126000AE
AG
581126000AG
AH
581126000AH
AJ
581126000AJ
AK
581126000AK
AL
581125000AL
AM
581126000AM
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy
Systems, North America, Inc. Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited.
)
NVBA
Description
Distribution.
(24) Bullet Nose Circuit Breaker and/or TPS/TLS
Fuse +24V System Positions.
Distribution.
(3) GJ/218 Circuit Breaker +24V System Positions.
(rows 1, 2, 3 only)
Distribution.
(3) GJ/218 Circuit Breaker +24V System Positions.
(row 4 only)
Distribution.
(8) GJ/218 Circuit Breaker +24V System Positions.
(rows 3 and 4 [C and D])
Distribution.
(8) GJ/218 Circuit Breaker +24V System Positions.
(rows 1 and 2 [A and B] or rows 2 and 3 [B and C])
Distribution.
(2) TPH Fuse +24V System Positions.
[Need (1) List AH for up to (2) List AG if internal
load returns are required.]
Ground Bar Assembly for use with up to (2) List
AG, AJ, CG, or CJ if internal load returns are
required.
Distribution.
(2) TPH Fuse +24V System Positions with Load
Shunts. [Need (1) List AH for up to (2) List AJ if
internal load returns are required.]
Distribution.
(24) Bullet Nose Circuit Breaker and/or TPS/TLS
Fuse +24V System Positions.
(no ground return busbar provided)
Ground Bar Assembly for use with up to (2) List AK
if internal load returns are required.
Distribution.
(20) Bullet Nose Circuit Breaker and/or TPS/TLS
Fuse +24V System Positions.
(1) Bullet Nose Circuit Breaker and/or TPS/TLS
Fuse 3-Pole +24V Input Disconnect Position.
Page 11 of 123
SAG581126000
Issue AD, November 23, 2009
Low
Single
Volt.
Battery
or Dual
Load
Disc.
Voltage
Disc.
Single
No
Single
No
Single
No
Single
No
Single
No
Single
No
N/A
No
Single
No
Single
No
N/A
No
Single
No
Home
No
No
No
No
No
No
No
No
No
No
No