RRP 70 Horizontal Transport Entrance Sensor and
Top Tray Full Sensor

Figure 11-12 H-Tra Entrance and Top Tray Full Sensor

Removal
1.
Remove the Horizontal Transport Top Open and Front Cover (RRP 67, on
page 11-325).
2.
Remove the two screws securing the Horizontal Transport Entrance Upper
Cover (RRP 68, on page 11-326).
3.
Remove the Entrance Sensor Cover, pry up on the locking tab while
pressing firmly towards the entrance end of the transport.
4.
Disconnect the wiring harness connector.
5.
Press down on the two locking tabs located at the top of the sensor, press
up on the two locking tabs at the bottom of the sensor and remove the
sensor.
Top Tray Sensor
1.
Disconnect the wiring harness.
2.
Remove one screw and remove the sensor bracket and sensor.
Replacement
Note
When replacing the sensor be sure the harness guide is
engaged into the cover.
11-328