Specifying the initialization method
The INIT can specify the method of defect processing executed by this command in the "FmtData
(format data)" bit and "CmpLst (complete list)" bit of CDB byte 1 and the "Defect List Format" field.
When "1" is specified in the "FmtData (format data) bit, it indicates that the format parameters (header
and defect list), described later, are transferred from the INIT when this command is executed. When
this bit's specification is "0," it indicates that the format parameters are not transferred.
When the "CmpLst (complete list)" bit is "1", it indicates that the previously existing G List is replaced
with the defect list (D List) transferred from the INIT when this command is executed. When this bit is
"0," the contents of the D List are added to those of the previously existing G List.
The "Defect List Forma" field specifies the format of the defect list (D List) transferred from the INIT
when the "FmtData (format data)" bit is "1." Any one of the following formats can be specified for the
defect list.
Defect List Format
0
1
1
If (0,0,0) is specified in the Defect List Format field and a value other than 0 is specified in "Defect List
Length" in the Format parameters, this command is terminated with a CHECK CONDITION status
(ILLEGAL REQUEST / Invalid field in parameter list).
The "Interleave factor" field in the CDB specifies the method of positioning logical data blocks in
physical sectors on the disk media. Whichever value is specified in this field, the IDD does not apply
sector interleave, but physically positions logical data blocks continuously in continuous sectors.
C141-C010
0
0
Block Address Format
0
0
Byte Distance from the Index Format
0
1
Physical Sector Address Format