Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive Scsi Logical Interface Specifications page 188

Specifications
Hide thumbs Also See for MAX3073NC - SCSI,80, Dell DC961,Hard Drive:
Table of Contents

Advertisement

Parameter Data Formats
f. PER (post error)
"1" : When several errors (errors related to the disk drive), which were recovered from normally
through the IDD's error recovery processing, have been detected, a CHECK CONDITION
status is reported when execution of that command is completed. In the sense data generated
at this time, the sense key indicates "RECOVERED ERROR [=1]" and the content of the first
error to be corrected successfully is reported.
"0" : Even when several errors (errors related to the disk drive), which were recovered from
normally through the IDD's error recovery processing, have been detected, that command is
completed with a GOOD status and the contents of the recovered errors are not reported.
g. DTE (disable transfer on error)
"1" : Even when several errors on the disk drive, which were recovered from normally through the
IDD's error recovery processing, have been detected, execution of that command terminates at
that point.
"0" : When several errors on the disk drive, which were recovered from normally through the IDD's
error recovery processing, have been detected, execution of that command is continued.
The IDD disregards this bit and operates according to the default value (=0).
h. DCR (disable correction)
"1" : Even when a correctable data check has been detected, data correction according to the ECC is
prohibited. However, On-the-fly correction processing is not prohibited.
"0" : When a correctable data check has been detected, data correction according to the ECC is
applied.
The IDD disregards this bit and operates according to the default value (=0).
i.
Number of retries during read
This parameter specifies the number of retries that should be executed for "Data Check" type errors
detected in read operations on the disk media. The number of retries specified in this parameter is
the maximum number of times reading is retried for each individual portion of data in each logical
data block. If the IDD cannot perform correction of the data On-the-fly for each portion of data in
the data block, it retries the reading of those portions. The reread retry is executed the number of
times specified by the drive parameter internally by the IDD before this retry is executed, so actually
the retry is executed the number specified here plus the number of internal retries.
The value specified in this parameter is applicable to the READ/READ EXTENDED commands and
the read test in the SEND DIAGNOSTIC command.
When the page length in Page 1 is specified as X '06,' the value specified in this field is copied to the
"Number of retries during WRITE" on this page and "Number of retries during VERIFY" on Page 7.
4-4
C141-C010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maw3073Maw3147Maw3300Max3036Max3073Max3147 nc series