Mode Select (15) - Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive Scsi Logical Interface Specifications

Specifications
Hide thumbs Also See for MAX3073NC - SCSI,80, Dell DC961,Hard Drive:
Table of Contents

Advertisement

3.1.5

MODE SELECT (15)

Bit
7
Byte
0
1
2
0
3
0
4
5
0
This command performs setting and changing of each type of parameter related to disk drive physical
attributes, data format, timing of SCSI bus disconnect/reconnect processing and error recovery
procedures, etc. The INIT can know the types of parameters, the current settings of each parameter and
the types of parameters which can be changed, and the ranges for such changes, etc. by using the MODE
SENSE or MODE SENSE EXTENDED command.
The data (MODE SELECT parameters) transferred from the INIT to the IDD by this command, are
configured from a "Header," "Block Descriptor" and one or more "Page Descriptors" which describe
each parameter, each of which will be explained later.
When the "PF (page format)" bit in CDB byte 1 is "1," it indicates that the MODE SELECT parameters
transferred from the INIT by this command are in the "Page Descriptor" format. The IDD disregards the value
specified in this bit and regards the MODE SELECT parameters transferred from the INIT as being in the
"Page Descriptor" format and executes this command.
The "SP (save pages)" bit in CDB byte 1 specifies whether or not to save the MODE SELECT
parameters specified in this command on the disk. It is possible for the IDD to save all the MODE
SELECT parameters described in the "Page Descriptor" (except for those on page C), but this bit's
specification is valid only for parameters other than "Format parameters (Page 3)" and "Drive parameters
(Page 4: excluding byte 17)."
If "1" is specified in the "SP" bit, the parameters transferred from the INIT are saved to the disk when
this command is executed, except for "Format parameters (page 3)" and "Drive parameters (Page 4:
excluding byte 17)." When the "SP" bit is "0," these parameters are not saved to the disk. On the other
hand, as for "Format parameters (Page 3)" and "Drive parameters (Page 4: excluding byte 17),"
regardless of the specification of the "SP" bit when this command is executed, these parameters are
always saved to the disk when the FORMAT UNIT command is executed.
The "Parameter length" field of the CDB specifies the total byte length of the MODE SELECT
parameters transferred from the INIT by this command. If zero is specified in the "Parameter length"
field, this command is terminated normally without data transfer being executed with the INIT. The
MODE SELECT parameters have specifically defined formats and lengths, as explained by the
descriptions of each page descriptor in this item, and the INIT must always specify (transfer) those
formats and lengths.
C141-C010
6
5
4
LUN
PF
0
0
0
0
0
0
Parameter List Length
0
0
0
3.1 Control/Sense Commands
3
2
X'15'
0
0
0
0
0
0
0
0
1
0
0
SP
0
0
0
0
0
Link
3-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maw3073Maw3147Maw3300Max3036Max3073Max3147 nc series

Table of Contents