Output Terminal Configuration - Hitachi L200 Series Instruction Manual

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for L200 Series:
Table of Contents

Advertisement

Output Terminal Configuration

The inverter provides configuration for logic (discrete) and analog outputs, shown in the
table below.
Func.
Name /
Code
SRW Display
C021 Terminal [11] function
OUT-TM 11
C022 Terminal [12] function
OUT-TM 12
C026 Alarm relay terminal
function
OUT-TM RY
C028 [AM] signal selection
AM-KIND
The output logic convention is programmable for terminals [11], [12], and the alarm
relay terminals. The open-collector output terminals [11] and [12] default to normally
open (active low), but you can select normally closed (active high) for these terminals in
order to invert the sense of the logic. You can invert the logical sense of the alarm relay
output as well.
Func.
Name /
Code
SRW Display
C031 Terminal [11] active
state
O/C-11
C032 Terminal [12] active
state
O/C-12
C036 Alarm relay active state Select logic convention, two
O/C-RY
"C" Function
Description
FA1
10 programmable functions
available for logic (discrete)
RUN
outputs (see next section)
AL
Two available functions:
00... Actual motor speed
F
01... Motor current
(see after next section)
"C" Function
Description
Select logic convention, two
option codes:
00... normally open (NO)
NO
01... normally closed (NC)
Select logic convention, two
option codes:
00... normally open (NO)
NO
01... normally closed (NC)
option codes:
NC
00... normally open (NO)
01... normally closed (NC)
L200 Inverter
Defaults
Run
Mode
–FEF
–FU
Edit
(EU)
(USA)
01
01
[FA1]
[FA1]
00
00
[RUN]
[RUN]
05
05
[AL]
[AL]
00
00
output
output
freq.
freq.
Defaults
Run
Mode
–FEF
–FU
Edit
(EU)
(USA)
00
00
00
00
01
01
3–47