Having two motor profiles lets you store two "personalities" for motors in one inverter's
memory. The inverter allows the final selection between the two motor types to be made
in the field through the use of an intelligent input terminal function [SET]. This provides
an extra level of flexibility needed in particular situations. See the following table.
Parameters for the second motor have a function code of the form x2xx. They appear
immediately after the first motor's parameter in the menu listing order. The following
table lists the parameters that have the second parameter register for programming.
Function Name
Multi-speed frequency setting
Acceleration (1) time setting
Deceleration (1) time setting
Acceleration (2) time setting
Deceleration (2) time setting
Select method to use Acc2/Dec2
Acc1 to Acc2 frequency transition point
Dec1 to Dec2 frequency transition point
Level of electronic thermal setting
Electronic thermal characteristic
Torque boost select
Manual torque boost value
Manual torque boost frequency adjustment
V/f characteristic curve selection
iSLV voltage gain
iSLV slip compensation
Base frequency setting
Maximum frequency setting
Frequency upper limit setting
Frequency lower limit setting
Motor capacity
Motor poles setting
Motor stabilization constant
L200 Inverter
Parameter Codes
1st motor
2nd motor
A020
A220
F002
F202
F003
F203
A092
A292
A093
A293
A094
A294
A095
A295
A096
A296
B012
B212
B013
B213
A041
A241
A042
A242
A043
A243
A044
A244
A046
A246
A047
A247
A003
A203
A004
A204
A061
A261
A062
A262
H003
H203
H004
H204
H006
H206
4–57