“H” Group Motor Constants - Hitachi L200 Series Instruction Manual

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for L200 Series:
Table of Contents

Advertisement

Func.
Name
Code
C149
Output relay OFF delay R/W Range is 0.0 to 100.0 sec.
Note 1:
Assume that the inverter current rating is 10000 (for C041).
The following table lists the holding registers for the "H" Group Motor Constants.
Func.
Name
Code
H003
Motor capacity
H203
Motor capacity, 2nd
setting
H004
Motor poles setting
H204
Motor poles setting, 2nd
motor
H006
Motor stabilization
constant
H206
Motor stabilization
constant, 2nd motor
"C" Group Intelligent Terminal Functions
R/W
Description
"H" Group Motor Constants
R/W
Description
R/W Thirteen selections:
0..... 0.20 kW
R/W
1..... 0.37 kW
2..... 0.40 kW
3..... 0.55 kW
4..... 0.75 kW
5..... 1.10 kW
6..... 1.50 kW
7..... 2.2 kW
8..... 3.0 kW
9..... 3.7 kW
10... 4.0 kW
11... 5.5 kW
12... 7.5 kW
R/W Four selections:
2 / 4 / 6 / 8
R/W
R/W Motor constant (factory set),
range is 0 to 255
R/W
B–39
L200 Inverter
Network Data
Reg.
Range
Res.
00F7h
0 to 1000 0.1 sec
Network Data
Reg.
Range
Res.
00D9h
0 to 12
00DAh
0 to 12
00DBh
2, 4, 6,
1 pole
8
00DCh
2, 4, 6,
1 pole
8
00DDh 0 to 255
1
00DEh 0 to 255
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents