Hitachi L200 Series Instruction Manual page 242

Single-phase input 200v class; three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for L200 Series:
Table of Contents

Advertisement

B–26
ModBus Data Listing
Func.
Code
A015
Pot./O–L input start
frequency enable
A016
External frequency
filter time constant
A020
Multi-speed 0 setting
A220
Multi-speed 0 setting,
2nd motor
A021
Multi-speed 1 setting
A022
Multi-speed 2 setting
A023
Multi-speed 3 setting
A024
Multi-speed 4 setting
A025
Multi-speed 5 setting
A026
Multi-speed 6 setting
A027
Multi-speed 7 setting
A028
Multi-speed 8 setting
A029
Multi-speed 9 setting
A030
Multi-speed 10 setting
A031
Multi-speed 11 setting
A032
Multi-speed 12 setting
A033
Multi-speed 13 setting
A034
Multi-speed 14 setting
A035
Multi-speed 15 setting
A038
Jog frequency setting
A039
Jog stop mode
A041
Torque boost select
A241
Torque boost select, 2nd
motor
Holding Registers for "A" Group Standard Functions
Name
R/W
R/W Two options; select codes:
00... Use offset (A011 value)
01... Use 0 Hz
R/W Range n = 1 to 8, where n =
number of samples for avg.
R/W Defines the first speed of a
multi-speed profile, range is
0.0 / start frequency to 400 Hz
A020 = Speed 0 (1st motor)
R/W Defines the first speed of a
multi-speed profile, range is
0.0 / start frequency to 400 Hz
A220 = Speed 0 (2nd motor)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
range is 0.0 / start frequency to
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W Defines limited speed for jog,
range is 0.00 / start frequency
to 9.99 Hz
R/W Define how end of jog stops
the motor; three options:
00... Free-run stop
01... Controlled deceleration
02... DC braking to stop
R/W Two options:
00... Manual torque boost
R/W
01... Automatic torque boost
Description
Defines 15 more speeds,
400 Hz.
A021= Speed 1...
A035 = Speed 15
Network Data
Reg.
Range
Res.
0038h
0, 1
0039h
1 to 8
1
sample
003Ah
0 / start
0.1 Hz
freq. to
4000
003Bh
0 / start
0.1 Hz
freq. to
4000
003Ch
0 / start
0.1 Hz
freq. to
003Dh
4000
003Eh
003Fh
0040h
0041h
0042h
0043h
0044h
0045h
0046h
0047h
0048h
0049h
004Ah
004Bh
0 / start
0.01 Hz
freq. to
999
004Ch
0, 1, 2
004Dh
0, 1
004Eh

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents