5.
Initial screen changes as below.
Figure 5-34. USB ID Readout Screen
6.
Write-down the indicated USB ID, and once quit the adjustment program.
7.
Replace to new main board.
8.
Setup the adjustment program again. Main screen (Figure 5-2) appears.
(Refer to Section 5.2.1.)
9.
Select "Adjustment", and then "Input USBG ID". Then press "O.K." button on the
program screen.
Adjustment
10. Following screen appears.
Figure 5-35. USB ID/Serial Number Input Mode
11. Input the original USB IDs that you wrote-down at step 6, then press "O.K." on the
program screen.
12. Program screen changes as below.
Figure 5-36. USB ID/Serial Number Input Mode 2
Adjustment