EPSON Stylus COLOR C70/C80
If the Linear Scale is pulled out from the right side, the Extension
Spring 1.494 may be damaged, so always pull it out from the left
side.
Securing Position
(Step 1)
Step 3
Extension Spring
1.494
Linear Scale
CR Motor
[Front-Left side]
Figure 4-41. Liner Scale Removal
When installing the Extension Spring to the Liner Scale, be careful
not to twist the end of the Spring.
6.
Carefully peel off the double-sided tape on the FFC, and disconnect the FFC from
the Rear of the Carriage Unit.
7.
Disconnect the FFC from the connector on the Print Head Control Board at the
rear of the Carriage Unit.
Disassembly and Assembly
Securing
Position
Linear Scale
(Step 2)
[Front-Right side]
When the Carriage Unit has been completely removed and is being
re-installed, make sure that you first connect the FFC to the
connector on the Print Head Control Board at the Rear of the
Carriage Unit. Then install the Guide Shaft to the Carriage Unit
and secure it to the Printer Mechanism. If you try to connect the
FFC after the CR and the CR Shaft have been installed, it will not
be possible to insert it correctly; and if it is inserted at an angle,
damage to the Head Shaft may occur.
Disassembly
Step 1
FFC
Step 2
Figure 4-42. FFCs Removal
Revision A