Epson Stylus Color C70 Service Manual page 119

Hide thumbs Also See for Stylus Color C70:
Table of Contents

Advertisement

EPSON Stylus COLOR C70/C80
If the intention is to remove the Carriage Unit as a single block,
there is no need to remove the Pulley Driven Holder Unit from
the Pulley Driven Holder. However, if CR Guide Shaft and
Carriage Unit are being replaced because the Page Counter or
Protection Counter is showing its maximum serviceable limit
value or over, it is recommended that the Pulley Driven Unit
(which is a consumable part) is also removed from the Pulley
Driven Holder at this time.When installing the CR Guide Shaft
to the Carriage Unit, the Oil Pad should be installed to the base
at the rear of the Carriage Unit.
This product has a page counter, but there is no upper limit, so
no upper limit errors can occur. The function is provided as
reference.
12. Remove the Spacer that are securing the PG Lever.
13. First remove torsion spring 141.1, and then pull the PG lever to the left to remove
it. At this time, it is easier to remove torsion spring 141.1 if the PG lever is moved
to the + side (rear).
+ Position
Dislocation Position
Spacer
Figure 4-46. Torsion Spring 141.1 and PG Lever Removal
14. Remove the screw (2) (CBS 3x6 {8±1 kgf.cm}) with washer that is securing the
PG adjust bushing in position.
Disassembly and Assembly
15. While pulling the PG Adjust Lever forward, turn it counterclockwise to disengage
16. Lower the PG Adjust Lever Support Plate together with the CR Guide Shaft to
PG Lever
Torsion Spring 141.1
Disassembly
it. Once it has been disengaged, remove the PG Adjust Lever.
C.B.S 3x6
Figure 4-47. PG Adjust Lever Removal
disengage from the Hook, and then slide the PG Adjust Lever Support Plate
forward to remove it.
PG Adjust Lever Support Plate
2
1
Figure 4-48. PG Adjust Lever Support Plate Removal
Revision A
PG Adjust Lever
[Left side]
Hook
CR Guide Shaft
119