3.4
Connect the control box to the main switch
2
5
CAUTION !
Only trained personnel or electricians may work on the electric
equipment of the automatic bartacker.
The mains plug must be unplugged!
1
–
Take off the switching knob.
Loosen the screw 2 in the knob in order to remove.
–
Remove the cover 3 from the main switch.
Unlock the locking bar in drill-hole 4 with a screwdriver in order to
remove.
–
Run the cable from the control box into the cable duct.
–
Insert the cable in the main switch.
–
Connect the cable wires from the control box to the
screws "T1" and "T2".
–
Connect the protective-earth conductor of the control box in
the main switch.
–
Put the cover on the mains switch again.
–
Put on the switching knob 1 and screw it tight.
–
Put on the cover of the cable duct.
4
3
2
7