Elo TouchSystems Entuitive ET1725L Series User Manual page 111

17" lcd desktop touchmonitor with magnetic swipe reader
Table of Contents

Advertisement

MagTek Device Drivers for Windows
Property
Access
c_write
c_wr_secure
capitalize
R/W
card_stat
chk_account
chk_amount
chk_bankid
chk_data
chk_format
R/W
chk_mod10
chk_number
chk_routing
chk_status
chk_transit
cmd_pending
dblpinentry
R/W
dev_status
dev_version
enable_cmc7
R/W
12
R
if the device can encode a magnetic card in either LoCo or HiCo;
1
if the device can encode a magnetic card in only the setting
2
indicated in
wr_coer
R
if the device does not support secure mode;
0
if the device can switch between secure and non-secure mode
1
(see
wr_secure
if the device only operates in the secure mode.
2
Set this to
to prevent the driver from capitalizing the data for the
0
and
read
write
(enable capitalization).
1
R
Current card sensor status:
= not blocked,
0
R
Check account number from check (MICR).
R
Check amount from check (MICR).
R
Bank ID number from the transit field (MICR).
R
Output data string as received from MICR reader (MICR).
Indicates the format of the check data. Set to
this property is modified by the application, the
(except
chk_data
R
Mod10 check digit from the transit field (MICR).
R
Check number (MICR).
R
Routing number from the transit field (MICR).
R
2-digit status code from the check just read (MICR).
R
Transit number from check (MICR).
R
Command pending–indicates which command, if any, is pending.
If none is pending, the second argument will be null:
Set to
to enable double PIN entry such as when requesting a new
1
PIN; set to
when verifying a customer's PIN (IntelliPIN).
0
R
Device status.
other value indicates a device-specific error. If the device fails to
respond, a null value is reported:
R
Device version string. This value is read directly from the device,
if the device supports a version string.
string read from the device will be replaced with
will be useful in reporting operational problems to MagTek.
Set this property to
disable it. This is used for international checks; see MICR manual
for more information. (MICR)
Description
);
commands. The default value for this property is
= blocked (PPINSERT).
1
and
chk_status
/get
cmd_pending<LF>
means device is connected and operational. Any
0
/get
dev_status<LF>
to enable CMC-7 characters decoding,
1
by default. If
6500
properties
chk_xx
) will be set to null. (MICR)
characters in the
<CR>
. This property
/
to
0

Advertisement

Table of Contents
loading

Table of Contents