n n Reassembling notes
•
Before connecting each of the CIS harnesses to the relay PCB, be sure to fit its ferrite core
over the cable clip. As shown on page III-27, in the order of the blue, yellow, and red CIS
harnesses, fit their ferrite cores over the cable clip and then connect those harnesses to the
relay PCB.
•
After routing the CIS harnesses and WB motor harness, make sure that those harnesses and
their ferrite cores do not interfere with the white sheet and frames, respectively.
•
When securing the lower support frame to the side frames, sandwich the spacers between
them as shown on page III-26.
•
When securing the lower cover, temporarily tighten the three shoulder screws (shown on page
III-26) in the center screw hole and outer screw holes, center the lower cover relative to the
corner covers, and then firmly tighten those screws.
[ 3 ] Removing the lower pipe and WB motor
Removing the lower corner plates and lower frame
(1) Remove the lower corner plates R and L (two cup S taptite screws, M3x10 from each plate).
III - 29