Brady BBP81 User Manual page 74

Hide thumbs Also See for BBP81:
Table of Contents

Advertisement

68
Configuration
Control Panel Parameters
Parameter
Y882746
Table 12 • Printer Parameters (Page 15 of 22)
Action/Explanation
Set Data Bits
This setting applies only when the serial port is used. The data bits of the
printer must match the data bits of the host computer for accurate
communications to take place. Set the data bits to match the setting being
used by the host computer.
Default Value: 8 BITS
Selections: 7 BITS, 8 BITS
To change the value shown:
1. Press
SELECT
to select the parameter.
2. Press
PLUS (+)
3. Press
to accept any changes and deselect the parameter.
SELECT
Set Parity
This setting applies only when the serial port is used. The parity of the
printer must match the parity of the host computer for accurate
communications to take place. Select the parity that matches the one being
used by the host computer.
Default Value: NONE
Selections: EVEN, ODD, NONE
To change the value shown:
1. Press
SELECT
to select the parameter.
2. Press
PLUS (+)
3. Press
to accept any changes and deselect the parameter.
SELECT
Set Host Handshake
This setting applies only when the serial port is used. The handshake
protocol of the printer must match the handshake protocol of the host
computer for communication to take place. Select the handshake protocol
that matches the one being used by the host computer.
Default Value (ZPL, XML): RTS/CTS XON/XOFF
Selections (ZPL, XML):XON/XOFF, DSR/DTR, RTS/CTS
Default Value (EPL): DTR & XON/XOFF
Selections (EPL): DTR & XON/XOFF, DTR
To change the value shown:
1. Press
SELECT
to select the parameter.
2. Press
PLUS (+)
3. Press
to accept any changes and deselect the parameter.
SELECT
BBP81 User Manual
or
MINUS (-)
to toggle between the options.
or
MINUS (-)
to scroll through the options.
or
MINUS (-)
to scroll through the options.
5/13/08

Hide quick links:

Advertisement

Table of Contents
loading