MERLIN LEGEND Communications System Release 6.0
Maintenance and Troubleshooting 555-660-140
Control Unit Problems
Module Problems
— In-progress calls are dropped if all of the calling parties on the call
originate and terminate on the module being reset.
— If a call is using a line or extension on the module being Reset and
another line and/or extension is involved in the call, the call on the
module being reset is put on hold. In this case, the module can be
removed and replaced. However, a demand test cannot be
performed, because the module is not busied-out.
Check the status of the reset module before performing a demand test.
Menu
Once you finish testing a module, you must restore it. Restoring a module
terminates the Busy-out or Reset condition. See
instructions.
Busy-Out
Summary
Console Procedure
PC Procedure
Appropriate Modules
Time Estimate
To busy-out a module, follow the steps below.
Menu
È Ä
no.
Type the slot no.
Any module that you are about to test
Once all calls are terminated, the busy-out completes
in less than 1 second. If calls in progress take too
long, ask the callers to hang up.
February 1998
''Restore'' on page 4-45
Dial the slot
Ä Ã
.
Issue 1
Page 4-39
for
Need help?