MERLIN LEGEND Communications System Release 6.0
Maintenance and Troubleshooting 555-660-140
Error Logs, Access Logs, and System Inventory
Error Logs
Table 2–2. Continued
Error
Codes
Description
Occurs during a broadcast reset.
The Red LED on the CPU will not turn
on, but the Red LED for the slot will
turn on.
Occurs during a hidden reset.
Action
If several of these occur:
Check that the system is in Hybrid/PBX
mode.
Validate the wiring and the connections.
Press the Restart Button (see "Restart" on
page 4–119).
Call the TSO's Telephony Services
Maintenance Group (800 242-2121) for
the procedures to unload and reload the
PBX driver.
If several of these occur, and the client
application has "slow" response time:
Validate the wiring and the connections.
Press the Restart Button (see the
procedure "Restart" on page 4–119).
Call the TSO's Telephony Services
Maintenance Group (800 242-2121) for
the procedures to unload and reload the
PBX driver.
Issue 1
February 1998
Page 2-25