Error Logs
Table 2–2 Continued
Error
Codes Description
The memory card voltage is incorrect.
Service on the link has been lost.
Service on the link has been lost.
Service on the link has been lost.
Service on the link has been lost.
Service on the link is uninitialized.
2–22
Error Logs, Access Logs, and System Inventory
Action
Reset the card and try again. Replace
the card if the problem persists and try
again. If the problem persists, replace
the processor.
Check the programmed SPID for
correctness. If it is incorrect, modify the
programming; otherwise, contact the
central office to correct the problem.
Check that the line is securely conected
to the port and that the LEDs on the
board show proper operation. If the card
appears to be working properly, check
that the line has been activated by the
central office .
The network is not responding to the
MERLIN LEGEND messages. Contact the
central office to correct the problem.
The network is not responding to the
MERLIN LEGEND messages. Contact the
central office to correct the problem.
The link is in the process of initializing. If
this error remains logged for more than a
half hour, try re-plugging the DSL. If the
problem persists, contact the central
office to correct the problem.
Continued on next page