AT&T MERLIN LEGEND Release 3.1 Maintenance And Troubleshooting Manual page 170

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.1:
Table of Contents

Advertisement

800 NI-BRI Module Problems
6 Interpret the test results
If the test completes successfully, the module's B-channels are functioning
properly. If a communication path fails, find the result code in Table 4–7, and
proceed as indicated.
7 Restore the module when all tests are completed.
When all of the lines have passed the test, the Red LED will remain on until the
CO reinitializes all of the lines.
Follow the procedures in Table 4–7 for examining each BRI line that has an
error and make corrections, if necessary, before rerunning the tool.
Table 4–7. NI-BRI Test Result Codes
Result
Description
Code
BRI facility provisioned
with functioning voice
and data capabilities
CO provisioning
error for voice calls on
that facility
4–80
Control Unit Problems
Corrective Action
No action required if voice and data functionalities are
expected.
This result indicates that facility is correctly administered
and established on Layers 1, 2, and 3. However, a
problem associated with the provisioning at the CO for
voice calls was detected. If the facility is intended to
provide voice calls, perform the following tests
(described later in this section) and record the results
before contacting the LEC:
Outgoing Voice Call Test
Incoming Voice Call Test
Continued on next page