Error Logs
Table 2–2 Continued
Error
Codes Description
The Translation card has the write
protection switch on.
A station is in program, administration,
or maintenance mode.
Unknown cause of a bad card.
A PCMCIA memory card is not
inserted.
The wrong type of PCMCIA memory
card is inserted.
The memory card has the write
protection switch on.
A station was in program mode.
Unknown cause of a bad card.
Action
Flip the write protection switch on the
card to off. It this problem persists try
another card and then replace the
processor module if the problem
remains.
Wait until the station changes mode.
Reset card and retry. It the problem
remains, try another card. If the problem
still remains, replace the processor
module.
Insert an memory card.
Remove the current card and insert the
appropriate card.
Flip the write protection switch on the
card to off. It this problem persists try
another card and then replace the
processor module if the problem
remains.
Wait until the station changes mode.
Reset card and retry. It the problem
remains, try another card. If the problem
still remains, replace the processor
module.
Error Logs, Access Logs, and System Inventory
Continued on next page
2–9
Need help?
Do you have a question about the MERLIN LEGEND Release 3.1 and is the answer not in the manual?