Error Logs
Table 2–2 Continued
Error
Codes Description
Outbound dialing problems on tie
trunks. For a tie trunk with delay dial or
wink start, the far end of the network
interface went on-hook before the
handshake was completed.
Outbound dialing problems on tie
trunks. For a tie trunk with delay dial
or wink start, the far end of the
network interface went on-hook
before the guard time elapsed.
Inbound dialing problems on tie and
DID trunks.
Communication problems occurred
between the processor and the
modules. Module may need to be
replaced.
Inbound dialing problems on tie and
DID trunks.
Inbound dialing problems on tie and
DID trunks.
Action
If problem persists, troubleshoot the tie
trunk configuration. Troubleshoot the far
end to see if it is working and translated
properly. Troubleshoot for faulty cable.
Replace the module.
Troubleshoot the far end of the network
interface to see whether it is working and
translated properly. Troubleshoot for wink
start and faulty cable. Troubleshoot the
far end of the network. Replace the
module.
Troubleshoot the far end of the
network interface to see if it is working
and translated properly. Troubleshoot
for faulty cable. Replace the module.
Turn the processor off and then on.
Repeat system programming procedure.
If problem persists, escalate to your
technical support organization.
Troubleshoot the far end of the
network interface to see if it is working
and translated properly. Troubleshoot
for faulty cable. Replace the module.
Troubleshoot the far end of the
network interface to see if it is working
and translated properly. Troubleshoot
for faulty cable. Replace the module.