Error Logs
Table 2–2 Continued
Error
Codes Description
This error indicates that the VMS
machine may be down.
May be noisy line or central office
problem.
More than half the trunks in the pool are
busy.
Incompatibility problem. The
specified video endpoint or UDM is
connedted to an 008 or 408 GS/LS
MLX with firmware vinatage 0x29.
At least one incompatibility problem
of type HER 0x1c05 detected. Turns
on CPU red LED.
2–10
Error Logs, Access Logs, and System Inventory
Action
No action required.
No action required. If problem persists,
troubleshoot the DID line and inform the
central office if necessary.
Troubleshoot trunk.
If
is logged and
is not, the firmware
upgrade should be retried. The circuit
module should be considered unreliable
until a successful upgrade is performed.
No action required.
No action required.
Replace the 008 or 408 MLX board with
one of another firmware vintage and
retire this permanent alarm manually.
Replace the 008 or 408MLX board with
one of another firmware vintage and
retire this permanent alarm manually.
Continued on next page