9. Service Mode
9.7.1
Start Up of the Serial Communication
Start up
1. Push the cursor key ↑ or ↓ to highlight Serial communication.
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
DIMMING
MORE...
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 9-17
2. Press ENTER to display the Serial Communication menu.
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 9-18
9.7.2
Baud rate Setting
Set up
To change the baud rate, handle as follow:
1. Push the cursor key ↑ or ↓ to highlight Baudrate.
SERIAL COMMUNICATION
PROJECTOR ADDRESS 001
BAUDRATE [115200]
INTERFACE STANDARD [RS232]
RS422 TERMINATION [ON]
Select with ↑ or ↓
then <ENTER>
<EXIT> to return
Menu 9-19
The actual baud rate will be displayed.
2. Press ENTER to toggle between the available baudrates.
Default : 9600
Available baud rates.
115200/57600/38400/19200/9600/4800/1200
116
R5976654 SLM R12+ 27/01/2005