C. TROUBLESHOOTING
C.1 Error codes
Overview
The following table gives an overview of some important error codes displayed on the LED display of the projector.
Error code
Description
2002
lamp start failed
6000
tilt switch
5002
ambient overtemperature
1100
Lamp overtemperature
3004
Top fan error
3005
Anode fan error
3006
Cathode fan error
2000
No LPS detected
2506
Lamp ignition failed
5001
DMD temperature
1102
Lamp insertion not OK
4004
SMPS EEPROM corrupt
4108
Group Fan 1 voltage too low
4109
Group Fan 2 voltage too low
4110
Group Fan 3 voltage too low
R5976654 SLM R12+ 27/01/2005
Caused by
•
hot restrike
•
lamp with many strikes
•
maximum run time exceeded
tilt angle is out of specifications
ambient temperature sensed by
the projector is above 45°C
lamp to hot
fan is not turning
failure
fan is not turning
failure
fan is not turning
failure
no communication with lamp power
supply
•
hot restrike
•
lamp with many strikes
•
maximum run time exceeded
•
temperature of one or more
DMD's is too high
•
temperature of one or more
DMD's is too low
•
Lamp not fully inserted
•
Screws not fully tightened
•
no EEPROM on SMPS
•
Wrong programmed
EEPROM on SMPS
C. Troubleshooting
Action
•
Let cool down the lamp for at
least 3 minutes.
•
Replace the lamp with a new
one
•
Correct projection installation.
•
Change the tilting so that the
tilt angle becomes within the
specifications..
Cool down the installation
environment.
Let cool down the lamp
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
•
Let cool down the lamp for at
least 3 minutes.
•
Replace the lamp with a new
one
If problem persists, call a qualified
service engineer
Let cool down the projector. If it
persists, call a qualified service
engineer
•
Check the lamp insertion
•
Tighten the screws
Download correct software
Call a qualified service engineer
Call a qualified service engineer
Call a qualified service engineer
147