To enable MAC Authentication:
1. Click Security > 802.1X Setting. The 802.1X Setting Page opens:
The 802.1X Setting Page contains the following fields:
Field
802.1X
QuietPeriod (0-65535) sec
SuppTimeout (1-65535) sec
ServerTimeout (1-65535) sec
MaxReq (1-10) times
TxPeriod (1-65535) sec
ReAuthPeriod (300 - 4294967295) sec
ReAuthEnabled
DGS-3100 Series Gigabit Stackable Managed Switch User Manual
Description
Indicates if 802.1X is enabled on the device. The possible field values are:
Enabled — Enables 802.1X (and MAC Authentication) on the device.
Disabled —Disables 802.1X on the device. This is the default value.
Indicates the number of seconds that the device remains in the quiet state
following a failed authentication exchange. The possible field range is 0-
65535. The field default is 60 seconds.
Indicates the amount of time that lapses before EAP requests are resent to
the supplicant. The field value is in seconds. The field default is 30 seconds.
Defines the amount of time that lapses before the device re-sends a request
to the authentication server. The field value is specified in seconds. The
field default is 30 seconds.
Displays the total amount of EAP requests sent. If a response is not received
after the defined period, the authentication process is restarted. The field
default is 2 retries.
Defines the amount of time (in seconds) that lapses before EAP requests are
resent. The field default is 30 seconds.
Displays the time span (in seconds) in which the selected port is re-
authenticated. The field default is 3600 seconds.
Indicates if ports/MAC address can be re-authenticated after the port/MAC
address authentication has timed out. The possible field values are:
Enabled — Enables re-authenticating the port or MAC addresses after
the port or MAC address authentication has timed out. This is the default
value.