Field
LLDP Status
LLDP Forward Status
Message TX Interval
Message TX Hold Multiplier
LLDP TX Delay
LLDP Reinit Delay
2. To configure LLDP Global parameters, select Enabled in the LLDP Status field and click
is enabled, and the device is updated.
3. To configure the LLDP packet forwarding status when LLDP is disabled, define the LLDP Forward Status field
and click
4. To configure LLDP Global parameters when LLDP is enabled, define the Message TX Interval, Message TX Hold
Multiplier, LLDP TX Delay and LLDP Reinit Delay fields and click
status is defined, and the device is updated.

Defining LLDP Port Settings

The LLDP Port Setting Page displays LLDP port information and contains parameters for configuring LLDP port settings.
1. Click L2 Features > LLDP > LLDP Port Setting. The LLDP Port Setting Page opens:
DGS-3100 Series Gigabit Stackable Managed Switch User Manual
Description
Specifies the LLDP status on the device. The possible field values are:
Enabled — Enables LLDP on the device. This is the default.
Disabled — Disables LLDP on the device.
Specifies the LLDP packet forwarding status when LLDP is disabled on the device.
The possible field values are:
Enabled — Enables LLDP packet forwarding on the device.
Disabled — Disables LLDP packet forwarding on the device.
Defines the LLDP message update transmission interval in seconds. The possible
field values are 5 – 32768 seconds. The default is 30 seconds.
Configures the Time-To-Live (TTL) of an LLDP packet, which is the time interval
that a receiving device holds an LLDP packet before discarding it. The TTL is
defined as the Message TX Hold Multiplier times the Message TX Interval. The
possible field values are 2 – 10. The default is 4.
Defines the time delay in seconds between successive LLDP frame transmissions
initiated by value or status changes. The possible field values are 1 – 8192 seconds.
The default is 2 seconds.
Defines the time interval in seconds before reinitializing an LLDP transmission after
LLDP is disabled. The possible field values are 1 – 10 seconds. The default is 2
seconds.