NETGEAR FS728TPv2 Software Administration Manual page 150

Fs728tp software administration manual
Hide thumbs Also See for FS728TPv2:
Table of Contents

Advertisement

To display the TACACS+ Server Configuration page, click Security  Management Security,
and then click the TACACS+  Server Configuration link.
To configure TACACS+ server settings:
To add a new TACACS+ server, select Add from the TACACS+ Server field, enter the
1.
IP address of the server to add, and click Apply.
The Add option is available if fewer than five TACACS+ servers are
Note:
configured on the system, and the Server Address field is only
available when Add is selected in the TACACS+ Server IP Address
field.
After you add one or more TACACS+ servers, additional fields appear on the TACACS+
Server Configuration page.
In the Priority field, specify the order in which the TACACS+ servers are used. A value of 0
2.
is the highest priority.
In the Port field, specify the authentication port number through which the TACACS+
3.
session occurs. The default is port 49, and the range is 0–65535.
In the Key String field, specify the authentication and encryption key for TACACS+
4.
communications between the FS728TP and the TACACS+ server. This key must match the
encryption used on the TACACS+ server. The valid range is 0–128 characters.
150 |
Chapter 5: Managing Device Security
FS728TP Smart Switch Software Administration Manual