Function No. 119 − 131
No.
Initial value
119
3
120
5
121
3000 (rpm)
(NOTE 38)
122
1000 (rpm)
(NOTE 38)
45
123
(degrees)
124*
0
125
0
126
1 (seconds)
127
100
128
0
129
0
130
0
131
–
(NOTE 38) Setting is enabled when Function No. 69 is set to "2".
*...
Settings indicated with " * " are enabled when the power is turned off and then back on.
Function No.132 − 136
The following function numbers show maintenance information.
No.
132
Cumulative power on time (Actual time = Displayed time x 10)
133
Cumulative operating time (Actual time = Displayed time xxxx x 10)
134
Cumulative grease-up running time (Time = Display xxxx x 1 hour) / Grease life estimate (%)
135
ROM version (x.xxx)
136
Set maximum speed history (rpm)
Setting range
–
[Do not change this setting.]
–
[Do not change this setting.]
200 – 5000
Speed when medium speed switch is on
(rpm)
200 – 5000
Speed when low speed switch is on
(rpm)
30 – 90
Servo lock release angle (Do not change this setting.)
(degrees)
Material edge sensor logic selection
0 – 1
0: Detects material absent
1: Detects material present
Servo lock operation
0: None
0 – 1
1: When stopped
2: When presser foot lifting signal is on
Servo lock timer setting
0 – 120
0: No timer operation
(seconds)
1–120: Timer operates (1–120 seconds)
–
[Do not change this setting.]
Flicker reduction function (when flickering occurs from fluorescent light)
0: None
1: Medium flicker reduction
0 – 3
2: Low flicker reduction
3: High flicker reduction
4: [Do not use this setting, otherwise the motor will overheat.]
-2 – 2
Motor acceleration gain [Do not change this setting.]
-2 – 2
Motor deceleration gain [Do not change this setting.]
–
[Do not change this setting.]
3. FUNCTION SETTINGS (OPERATION PANEL)
Setting details
Description of displays
S-7200B
20
Need help?
Do you have a question about the S-7200B and is the answer not in the manual?