Circuit Board Dip Switches - Brother RH-9800 Instruction Manual

Electronic eyelet button holer
Hide thumbs Also See for RH-9800:
Table of Contents

Advertisement

10-2. Circuit board DIP switches

Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the face plate of the control box. Touching areas where high voltages are present can result in
severe injury.
The ON/OFF positions of the DIP switches inside the front panel are checked only once when the power is turned on.
Any changes to the DIP switch positions will not be effective until the power is switched off and back on again.
Only one of DIP switch No.1, 2 and 3 is effective at any one time. They are effective in the order 1, 2, 3.
No.
ON/OFF
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
*1
4
OFF
ON
*2
5
OFF
ON
6
OFF
ON
7
OFF
ON
8
OFF
*1 The version of the PROM is given as "E1" or later.
*2 The version of the PROM is given as "D1" or later.
If the stitch length has been set to 39 mm or greater, it will be automatically changed to 38 mm if DIP switch No. 6 is
changed to ON.
* The machine is shipped from the factory with the DIP switches set as follows.
DANGER
Upper gimp guide present
Upper gimp guide not present
Upper thread nipper present
Upper thread nipper not present
Upper and lower thread trimming
Upper thread trimming
Material is remains pressed after sewing
Material is released after sewing
Needle bar returns to home position after set number of pieces sewn
Needle bar always returns to home position after each piece sewn
RH-9800
10. SUMMARY OF DIP SWITCHES
Description
Data initialization
Normal
Input check
Normal
Output check
Normal
1193Q
57

Hide quick links: