9-3. Adjusting the loop stroke

The loop stroke is the distance the needle bar rises from its lowest position to the position where the tips of the left and
right loopers are aligned with the center of the needle. The standard loop stroke is 2.7 mm. (The loop stroke may need
changing depending on the material and thread being used.)
* Carry out the adjustment in "9-2. Adjusting the needle and looper timing" before making this adjustment.
(1)
(2)
1. In the same way as in "9-2. Adjusting the needle and looper timing", move the needle bar to its lowest position with the
needle at the inside sewing position, and then use calipers to measure the distance between the end of the needle bar
(1) and the top of the needle bar bracket (2).
2. Add 2.7 mm to the value obtained in step 1. above.
3. Touch the end of the calipers (A) against the top of needle bar bracket (2), and then turn the upper shaft pulley until the
end of the needle bar (1) touches the edge of the calipers (B). Check that the tip of the left looper is aligned with the
center of the needle at this time.
4. In the same way, check that the tip of the right looper is aligned with the center of the needle when the needle is at the
outside sewing position.
(3)
(4)
0957Q
5. If the tips of the loopers are not aligned with the center of the needle, carry out the adjustment below.
Raise the machine head.
Loosen the two screws (3) of the lower shaft timing pulley, hold the upper shaft pulley so that it doesn't move, and then
turn the lower shaft cam (4) in the direction indicated by the arrow until the tip of the left looper (5) is aligned with the
center of the needle (6). Once they are aligned, tighten the two screws (3).
After adjusting, check that the screws have been adequately tightened.
Once this adjustment has been carried out, repeat the procedure given in "9-2. Adjusting the needle and looper
timing".
2.7 mm
(A)
RH-9800
9. STANDARD ADJUSTMENTS
(6)
(5)
(B)
0956Q
0958Q