Download Print this page

Allied Telesis AT-9900 Series Release Note page 4

At-8900 and at-9900 series software maintenance release note 276-03
Hide thumbs Also See for AT-9900 Series:

Advertisement

Features in 276-02
Software Maintenance Version 276-02 includes all resolved issues and enhancements in earlier versions, and the resolved issues and enhancements in the
following tables. In the tables, for each product series:
"Y" indicates that the resolution is available in Version 276-02 for that product series.
"-" indicates that the issue did not apply to that product series.
Level 1
CR
Module
Switch
CR00011691
Core,
CR00011694
Switch
CR00012097
Switch
Version 276-03
C613-10474-00 REV B
Level
1
Previously, if trunk ports were configured and/or STP was enabled, the CPU
flooded GARP frames in an incorrect manner, which could cause network loops.
This issue has been resolved. GMRP frames are (correctly) flooded, and GVRP
frames are now only flooded if GARP is disabled.
1
If the switch had learned a very large number of routes from BGP and the
interface went down, IP ran out of memory when recalculating the best routes
to use. This was exacerbated when the high memory usage triggered the BGP
backoff mechanism which in turn disabled the BGP peers, which caused IP to
recalculate even more routes. The switch eventually rebooted due to memory
exhaustion.
This issue has been resolved by improvements to memory allocation and IP route
queuing, and by enforcing limits on the number of IP routes.
1
When PIM6 was configured on the switch, and it received an IPv6 multicast
stream for which it had no downstream interface to forward the stream to, a
reboot could occur.
This issue has been resolved.