CR
Module
Level
CR00010996
Port
Authentication
CR00011040
Ping
CR00011068
SSL
CR00011111
IPX
CR00011213
PIM 6
Version 276-03
C613-10474-00 REV B
2
When port authentication was using a RADIUS server, it sometimes stopped
working after several hours. This was because port authentication generated
RADIUS Accounting Request (STOP) messages with an incorrect Acct-Session-
Time value.
This issue has been resolved.
2
When the router or switch was configured with multiple logical interfaces, it
chose the source address of the ICMP Echo Reply incorrectly in some
configurations.
This issue has been resolved.
2
Previously, there was a memory corruption issue in the SSL client and server
implementation.
This issue has been resolved.
2
Forwarding an 802.3 or ETHII encapsulated IPX packet over a VLAN to a remote
network occasionally caused the switch to reboot.
This issue has been resolved.
2
Previously, the switch treated a valid bootstrap message as a bad message if it
received the message on two or more interfaces, and when PIM6 operated in a
looped or network topology that had multiple unicast routes to the same
destination(s), it sometimes selected a sub-optimal route for RPF interface
selection for RP and BSR elections.
This issue has been addressed by an additional algorithm to deal with equal cost
multipath routes as follows:
a. if more than one route to the same given destination with equal cost exists,
then the route with highest nexthop IP address value will be selected.
b. if the nexthop IP address values are the same (the routes come from the same
device on different interfaces), then the routes with highest interface index will
be selected.
Description
Features in 276-01
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
-
-
-
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
-
-
Y
31
Y
-
Y
Y
Y
Y
Y
Y
Y
Y

Advertisement

loading

This manual is also suitable for:

At-9924tAt-9924spAt-9924t/4spAt-8900At-8948