Download Print this page

Allied Telesis AT-9900 Series Release Note page 13

At-8900 and at-9900 series software maintenance release note 276-03
Hide thumbs Also See for AT-9900 Series:

Advertisement

CR
Module
CR00012304
TPAD
CR00012319
IPv6
CR00012396
Firewall,
Software QoS
Version 276-03
C613-10474-00 REV B
Level
2
TPAD previously had issues when the LRC (Longitudinal Redundancy Check) at
the end of a transaction was 0x00 and the transaction was via the TCP port. The
transaction would stall in the box and eventually time out the X.25 call.
This issue has been resolved. TPAD transactions now accept an LRC with a value
of 0x00 and operate as normal.
2
If the router or switch received a packet that was destined for a link-local address
that did not exist, it tried to forward the packet. This caused it to reboot. For
example, if a user pinged a non-existent link-local address, the router or switch
rebooted.
This issue has been resolved by ensuring that the router or switch does not
attempt to forward or route packets destined for a link-local interface. Such
packets should not be forwarded because they are intended for the local link.
2
When the router or switch was running software QoS and performing NAT
through the firewall, it did not check egress classifiers against the pre-NAT
address of translated packets.
This issue has been resolved.