Replacing The Wwn Bezel - HP StorageWorks 2/64 - Core Switch Installation Manual

Hp storageworks core switch 2/64 and san director 2/128 installation guide (aa-rvusc-te, january 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

CAUTION:
properly oriented.

Replacing the WWN bezel

Use these steps to reinstall the WWN bezel.
1.
Orient the bezel on the chassis (see
standoffs on the chassis and tighten to finger-tight.
2.
In the CLI session, type continue to indicate that the replacement has been completed.
Please enter the word `continue' after the new WWN card has
been installed: continue
Restoring the information to the replacement FRU now,
please wait about 20 seconds to complete
Verifying the replacement FRU now...
WWN card hot swap is now complete.
FRU replacement completed successfully!
3.
Verify that the WWN card is correctly connected by checking the LEDs on the WWN card
to see if they reflect the status of the components.
NOTE:
The LEDs might take up to 2 minutes after WWN card installation to begin
functioning.
4.
Pack the faulty WWN card in the packaging provided with the new card and return it to
the switch supplier.
122
Installing FRUs
Do not force the installation. If the part does not install easily, ensure that it is
Figure
28); then, insert both retaining screws into the

Advertisement

Table of Contents
loading

Table of Contents