NOTE:
If necessary, remove the adapter on the serial cable to allow for a serial RJ45
connection.
d. Open the terminal emulator application and configure as follows:
• Bits per second: 9600
• Databits: 8
• Parity: None
• Stop bits: 1
• Flow control: None
8.
Log in to the new CP card as admin.
Fabric OS (swDir)
swDir login: admin
Password:
swDir:admin>
From the serial console for the new CP card, enter the haFailover command to fail the
9.
active CP card over to the new CP card.
10.Verify that the configuration has successfully propagated to the new CP card by checking
any configuration parameters for which you have specified nondefault values. To do this,
enter the configShow command followed by a filter (a text string in quotes) that relates to
the parameter: for example, configShow "fabric". This limits the command output to
entries that contain that text string.
NOTE:
Entering the configShow command without a filter prints out approximately 1000
lines. For more information about this command, refer to the HP StorageWorks command
reference guide for the Fabric OS version running on your switch.