Data Stored On The Wwn Card; Messages That Can Indicate Wwn Card Failure - HP StorageWorks 2/64 - Core Switch Installation Manual

Hp storageworks core switch 2/64 and san director 2/128 installation guide (aa-rvusc-te, january 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

Table 11

Data stored on the WWN card

Data
WWN values
Data about the chassis and WWN card
Ethernet and Fibre Channel IP address
information for the CP cards
History log information
Names of switch
NOTE:
For additional information about these commands, refer to the HP StorageWorks
command reference guide for the Fabric OS version running on your switch.
3.
If the error log or serial console display error messages that indicate problems with WWN
units (see
WWN units correspond to information specific to the WWN card and are displayed by
the chassisShow command. For additional information about this command, refer to the
HP StorageWorks command reference guide for the Fabric OS version running on
your switch.
Table 12

Messages that can indicate WWN card failure

Type of message
WWN unit fails its FRU (field
replaceable unit) header access.
WWN unit is being faulted.
WWN unit is not present or is not
accessible.
Writing to the FRU history log
(hilSetFruHistory) has failed.
76
Operating the switch
Table
12), the WWN card might have failed.
Related commands
wwn, chassisShow
chassisShow
ipAddrShow, ipAddrSet
historyShow, historyLastShow
switchName
Sample error message
0x24c (fabos): Switch: switchname, error
EM-I2C_TIMEOUT, 2, WWN 1 I2C timed out:
state 0x4
0x24c (fabos): Switch: switchname,
Critical EM-WWN_UNKNOWN, 1, Unknown WWN #2
is being faulted
0x24c (fabos): Switch: switchname, Error
EM-WWN_ABSENT, 2, WWN #1 not present
0x24c (fabos): Switch: switchname, Error
EM-HIL_FAIL, 2, HIL Error:
hilSetFruHistory failed, rc=-3 for SLOT 3

Advertisement

Table of Contents
loading

Table of Contents