2.
Enter fruReplace wwn from the active CP card and wait for the message Do you wish
to continue [y/n]? to appear; then enter y.
3.
Verify that the following has occurred:
• The prompt, "Please enter the word 'continue'..." appears in the CLI.
IMPORTANT:
Do not enter y to continue until the replacement WWN card is installed.
!
• All the LEDs on the WWN bezel turn off.
swDir>admin>frureplace wwn
This is the WWN card hot swap interface.
Continuing from this point will require the whole process
to be completed.
If this process is not complete due to system fails-over,
or CP power cycled, Please follow the recovery procedure
in Core Switch WWN Card Removal and Replacement document.
Do you wish to continue [y/N]? y
Backing up WWN card data, please wait about 25 seconds for
further instruction.
Ready to restore WWN card data, please make sure you have
a replacement FRU now.
If this session lost due to user aborted, please
reinitiate the invoking command and follow the
instructions to complete the operation.
Please enter the word `continue' when done: continue
Restoring the replacement FRU now, please wait about 20
seconds to complete
Verifying the replacement FRU now...
WWN card hot swap is now complete.
FRU replacement completed successfully!
These events indicate that data has been backed up and the card can be replaced.
4.
Unscrew both captive screws on the WWN bezel (see
away from chassis and set it aside.
The WWN card is visible.
Core Switch 2/64 and SAN Director 2/128 installation guide
Figure
28); then, pull the bezel
119